Seametrics PT2X Water Level Loggers

The Seametrics PT2X is ideal for observing flow patterns, testing pumps, and monitoring groundwater, well, tank and tidal levels.

Features

  • Measures water level and temperature
  • Internal data logger for 520,000 records
  • Optional internal AA batteries operate for ~1 year at 15-minute log interval

Details

The Seametrics PT2X is ideal for observing flow patterns, testing pumps, and monitoring groundwater, well, tank and tidal levels. A pressure and temperature sensor with integrated data logging, this sensor is constructed with 316 stainless steel, fluoropolymer, PTFE—providing highly accurate readings in rugged and corrosive field conditions.

Sensor:

  • Measures pressure, temperature, and time
  • Available in absolute, gauge, or sealed gauge
  • Thermally compensated—great where water temperatures vary, such as in streams or industrial tank applications
  • ± 0.05% FSO typical accuracy
  • Low power—2 internal AA batteries
  • External power options (12 VDC) with AA’s acting as backup
  • 316 stainless steel, fluoropolymer, and PTFE construction (titanium optional)
  • Available for both Modbus and SDI-12 protocols

Data Logger:

  • Non-volatile memory—your data will not be lost in the event of a power failure
  • Flexible, multi-phase logging sequences—measure at your specified intervals and save instructions to disk for reuse
  • Pause logging feature—temporarily pause the logging while repositioning or transporting sensor
  • Delayed start feature—state a specific future start time, making it easy to set several sensors to start at the same time

Cabling & Networking:

  • Wireless connectivity
  • RS485 network—allows several sensors to be networked together and provides much longer cable leads
  • Field-serviceable connectors—easily remove the connector, route cable through well seals, walls, or conduit, and then replace connector
  • Available cableless or with a variety of cable options, including polyethylene, polyurethane, and FEP

Software:

  • Comes with free Aqua4Plus control software to get up and running immediately
  • View your data in real-time
  • Easy export to spreadsheets and databases
  • Barometric compensation utility for use with absolute sensors
  • Update sensor via firmware while in the field—great for future updates or custom development

Parts


ImagePart#Product DescriptionQuote
2A317242A31724PT2X vented water level & temperature logger with stainless steel housing, 5 PSIG range, requires cable
2A317262A31726PT2X vented water level & temperature logger with stainless steel housing, 15 PSIG range, requires cable
2A317282A31728PT2X vented water level & temperature logger with stainless steel housing, 30 PSIG range, requires cable
2A317302A31730PT2X vented water level & temperature logger with stainless steel housing, 50 PSIG range, requires cable
2A317322A31732PT2X vented water level & temperature logger with stainless steel housing, 100 PSIG range, requires cable
2A317342A31734PT2X vented water level & temperature logger with stainless steel housing, 300 PSIG range, requires cable
2A317522A31752PT2X non-vented water level & temperature logger with stainless steel housing, 30 PSIA range, requires cable
2A317542A31754PT2X non-vented water level & temperature logger with stainless steel housing, 50 PSIA range, requires cable
2A317562A31756PT2X non-vented water level & temperature logger with stainless steel housing, 100 PSIA range, requires cable
2A317582A31758PT2X non-vented water level & temperature logger with stainless steel housing, 300 PSIA range, requires cable
2A327242A32724PT2X vented water level & temperature logger with titanium housing, 5 PSIG range, requires cable
2A327262A32726PT2X vented water level & temperature logger with titanium housing, 15 PSIG range, requires cable
2A327282A32728PT2X vented water level & temperature logger with titanium housing, 30 PSIG range, requires cable
2A327302A32730PT2X vented water level & temperature logger with titanium housing, 50 PSIG range, requires cable
2A327322A32732PT2X vented water level & temperature logger with titanium housing, 100 PSIG range, requires cable
2A327342A32734PT2X vented water level & temperature logger with titanium housing, 300 PSIG range, requires cable
2A327522A32752PT2X non-vented water level & temperature logger with titanium housing, 30 PSIA range, requires cable
2A327542A32754PT2X non-vented water level & temperature logger with titanium housing, 50 PSIA range, requires cable
2A327562A32756PT2X non-vented water level & temperature logger with titanium housing, 100 PSIA range, requires cable
2A327582A32758PT2X non-vented water level & temperature logger with titanium housing, 300 PSIA range, requires cable
2A337202A33720PT2X vented water level & temperature logger with stainless steel housing, 1 PSIG range with set-screw, requires cable
2A417202A41720PT2X vented water level & temperature logger with stainless steel housing, 1 PSIG range, requires cable & external power
2A417242A41724PT2X vented water level & temperature logger with stainless steel housing, 5 PSIG range, requires cable & external power
2A417262A41726PT2X vented water level & temperature logger with stainless steel housing, 15 PSIG range, requires cable & external power
2A417282A41728PT2X vented water level & temperature logger with stainless steel housing, 30 PSIG range, requires cable & external power
2A417302A41730PT2X vented water level & temperature logger with stainless steel housing, 50 PSIG range, requires cable & external power
2A417322A41732PT2X vented water level & temperature logger with stainless steel housing, 100 PSIG range, requires cable & external power
2A417342A41734PT2X vented water level & temperature logger with stainless steel housing, 300 PSIG range, requires cable & external power
2A417522A41752PT2X non-vented water level & temperature logger with stainless steel housing, 30 PSIA range, requires cable & external power
2A417542A41754PT2X non-vented water level & temperature logger with stainless steel housing, 50 PSIA range, requires cable & external power
2A417562A41756PT2X non-vented water level & temperature logger with stainless steel housing, 100 PSIA range, requires cable & external power
2A417582A41758PT2X non-vented water level & temperature logger with stainless steel housing, 300 PSIA range, requires cable & external power
2A427242A42724PT2X vented water level & temperature logger with titanium housing, 5 PSIG range, requires cable & external power
2A427252A42725PT2X vented water level & temperature logger with titanium housing, 15 PSIG range, requires cable & external power
2A427282A42728PT2X vented water level & temperature logger with titanium housing, 30 PSIG range, requires cable & external power
2A427302A42730PT2X vented water level & temperature logger with titanium housing, 50 PSIG range, requires cable & external power
2A427322A42732PT2X vented water level & temperature logger with titanium housing, 100 PSIG range, requires cable & external power
2A427342A42734PT2X vented water level & temperature logger with titanium housing, 300 PSIG range, requires cable & external power
2A427522A42752PT2X non-vented water level & temperature logger with titanium housing, 30 PSIA range, requires cable & external power
2A427542A42754PT2X non-vented water level & temperature logger with titanium housing, 50 PSIA range, requires cable & external power
2A427562A42756PT2X non-vented water level & temperature logger with titanium housing, 100 PSIA range, requires cable & external power
2A427582A42758PT2X non-vented water level & temperature logger with titanium housing, 300 PSIA range, requires cable & external power